Bioaerosol Monitoring Device AST12 China Factory and Professional Suppliers
Bioaerosol Monitoring Device AST12 China Factory and Professional Suppliers

Bioaerosol Monitoring Device AST12 China Factory and Professional Suppliers

Looking for reliable China suppliers? Our factory provides the AST-1-2 Bioaerosol Monitoring Device for real-time single particle measurement of bacteria, molds, and pollen using advanced fluorescence detection for precise air quality safety.

download to pdf
Details
Tags

The Bioaerosol Monitoring Device is a professional-grade instrument engineered for the high-precision detection and real-time monitoring of airborne biological particles. Utilizing advanced light-scattering and fluorescence detection technology, it effectively identifies trace amounts of mold, bacteria, spores, and pollen, providing critical data to ensure environmental safety and sterile conditions in high-stakes industries.

Designed for versatility and reliability, this device employs a dual-excitation wavelength and dual-emission band system, specifically optimized for detecting fluorophores such as tryptophan and NADH. Whether deployed in pharmaceutical clean rooms, healthcare facilities, or public transportation hubs, it delivers rapid response times and particle-by-particle data to safeguard public health and industrial productivity.

Detailed Parameters

ModelAST-1-2Detection ObjectsBacteria, spores, fungi, pollen, etc.
Particle Size0.5~10μmSensitivity≤50 biological particles/L
Sampling Flow2.5L/minResponse Time<3s
Working Temperature0℃~40℃Store Temperature-40℃~60℃
Communication ModeUART-TTLInput PowerDC 12V 2A (Power <10W)

Key Advantages

High Sensitivity

Detects trace amounts of mold and airborne bioaerosols with extreme precision using 405nm flash lamp excitation.

Rapid Response

Achieves a response time of less than 3 seconds, enabling immediate detection of biological threats.

Precise Technology

Optimized for tryptophan and NADH detection via two excitation wavelengths and two emission bands.

Real-time GUI

Graphical user interface provides real-time particle data and instrument health monitoring for maximum uptime.

Particle Detail

Captures specific data for particles 0.5 to 7µm, configurable for larger particles like pollen and fungal spores.

Zero Consumables

Low-maintenance operation with no consumables required, reducing long-term operational costs.

Product Gallery

Management Platforms

Pharmaceutical Grade

Ensures clean room standards are strictly met to prevent product contamination.

Hospital Surveillance

Monitoring airborne pathogens to reduce hospital-acquired infections.

Public Health Alert

Detecting potential airborne biological threats in public spaces and hubs.

Lab Research Control

Precise monitoring of biological particle concentration in controlled settings.

Food Safety Audit

Maintaining hygienic production environments to prevent biological contamination.

HVAC Air Quality

Ensuring ventilation systems maintain clean air standards via contaminant detection.

Investment Return Comparison

Monitoring MetricTraditional SamplingBioaerosol Monitoring Device
Detection SpeedDays (Lab Culture)
Operational CostHigh (Consumables)Low (Zero Consumables)
Labor IntensityManual CollectionAutomated Monitoring
Risk MitigationReactive ResponseProactive Prevention
Data GranularityAggregate ResultsParticle-by-Particle Data

Frequently Asked Questions

Q: What specific biological particles can the Bioaerosol Monitoring Device detect?

The device is designed to detect a wide range of bioaerosols, including bacteria, fungal spores, pollen, and other biological particles ranging from 0.5 to 10μm.

Q: How does fluorescence detection improve accuracy in medical device monitoring?

By targeting specific fluorophores like tryptophan and NADH, the device can distinguish biological particles from inert dust, significantly reducing false positives.

Q: Is this device suitable for continuous 24/7 monitoring in hospitals?

Yes, the device is built for continuous real-time monitoring with a graphical interface that tracks instrument health to ensure maximum operational uptime.

Q: What is the maintenance requirement for the AST-1-2 model?

The AST-1-2 is designed to be low-maintenance and operates without the need for consumables, making it cost-effective for long-term deployment.

Q: Can the device be integrated into existing building HVAC systems?

Yes, with its UART-TTL communication mode, the device can be integrated into smart building management systems to monitor and maintain air quality standards.

Q: In which industrial environments is bioaerosol monitoring most critical?

It is critical in pharmaceutical manufacturing, food processing, sterile healthcare wards, and biosecurity zones where airborne contamination poses a severe risk.

Ready to Enhance Your Bio-Security Standards?

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.